BPM-D03 Defibrillator Monitor
Lightweight, easy-to-use device for emergency cardiac care. Offers automated shock delivery, voice guidance, and rapid response features. Ideal for public spaces, clinics, and first aid kits.
Free shipping on orders over N100,000
- Satisfaction Guaranteed
- No Hassle Refunds
- Secure Payments
Specification:
|
Display Screen |
|
|
Type |
High-resolution display |
|
Size |
7 inches diagonally |
|
Sweep Speed |
25mm/sec |
|
Information |
Heat rate, lead/pads, alarm on/off, SpO2, AED functions and prompts, alarm selection and limits, delivered energy |
|
Defibrillator |
|
|
Waveform |
Biphasic |
|
Energy Display |
Monitor display indicates both selected and delivered energy |
|
Charge Prompt Type |
Voice and visual prompts |
|
Electrode Impedance Measurement Range |
0~250 ohms |
|
ECG Monitoring |
|
|
Patient Connection |
3-lead ECG cable, or 5-lead ECG cable, paddles |
|
Lead Selection |
Displayed on monitor, paddles, I, II, III, AVR, AVL, AVF, V |
|
ECG Size |
0.25, 0.5, 1, 1.5, 2, 4 cm/mV display on monitor |
|
Heart Rage |
20~300 BPM |
|
Heart Rate Alarm |
On/Off displayed on monitor, user-selectable |
|
Smart Alarms |
Beeper/voice prompts indicate shockable rhythm |
|
Battery |
|
|
Type |
Rechargeable, Ni-MH battery, 12V |
|
Operating Time |
For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring, Additional parameters will effect operating time with different functions |
|
SpO2 Module |
|
|
Measurement Range |
30~100%, ±2% between 80%~90%, others ±5% |
|
Alarm Range |
User set high limit and low limit |
|
Alarm Accuracy |
±10% within setting values |
|
Alarm Time Accuracy |
Less than 12 sec. |
|
Recorder |
|
|
Paper |
50mm thermal |
|
Speed |
12.5mm/sec, 25mm/sec, 50mm/sec; User-selectable 6-second delay |
|
Printing Method |
High-resolution, thermal array print head |
|
Print-out Modes |
Manual or automatic, user-configurable |
|
On/Off Control |
Front panel and paddle |
|
Automatic Function |
9-second recording initiated by alarm activation or defibrillator charge or defibrillator discharge |
|
AED Mode |
|
|
AED Function |
Auto analyze and charge X3 with programmable auto energy level selection, scree prompts, and voice prompts |
|
Shockable Rhythms |
Ventricular fibrillation Ventricular tachycardia QRS complex wave duration |
|
Charge Control |
Control on device front panel, press key on paddle |
|
Manual Mode |
|
|
Energy Selection |
Selectable at 2,5, 7, 10, 20, 30, 50, 70, 100, 150, 200, 300, 360 joules |
|
Synchronized Mode |
Synchronizes defibrillator pulse to patient’s R-wave. “ SYNC” message displayed on monitor |
BPM is the best Defibrillator Monitor supplier. Welcome your inquiry




























Reviews